한국의

한국의

Get a Quote
제품

핫 제품

회사 뉴스

Embarking on a New Chapter: DERVOS Relocates to Channel Pearl Plaza
Embarking on a New Chapter: DERVOS Relocates to Channel Pearl Plaza
2024-04-26

We are delighted to announce that our company is on the brink of a new beginning - the acquisition of a new office space. This marks a fresh start for our company's development, and we eagerly anticipate crafting a brighter future in this new environment. The selected location enjoys excellent geographic positioning, convenient transportation, and a pleasant environment. The choice of our new office space has been meticulously considered, aiming to provide our employees with a spacious and comfortable working environment while offering ample support and motivation for the company's development. Starting from April 15, 2024, our office address will be changed to: [Unit 3104, Channel Pearl Plaza, No.99 Yilan Road, Siming District, 361008, Xiamen City, Fujian Province, China]。This relocation is not only a natural choice for the continued development of our company, but also a testament to our confidence and aspirations for the future. The utilization of the new premises will further enhance internal collaboration and communication within the company, ignite the creativity and vitality of our team, and elevate our efficiency and service standards. We aim to deliver even higher-quality products and services to our customers and partners as a result. Finally, we would like to express our heartfelt gratitude for your long-standing support and trust in our company. We believe that this new beginning will bring forth fresh hope and opportunities. We will continue to uphold the principle of 'Customer First, Innovative Development', striving for excellence and working towards our long-term corporate goals. Let us join hands and work together to create a brighter future.

The Important Functions of Steam Trap Valves
The Important Functions of Steam Trap Valves
2024-04-17

A steam trap valve is a device designed on devices that require steam, which can automatically discharge condensate, air, and non condensable gases from the steam system and prevent steam from being discharged. Important Functions (1) Able to quickly remove condensate generated; (2) Prevent steam leakage; (3) Remove air and other non condensable gases. The necessity of using steam equipment to remove condensate and air: (1) Prevent water hammer: If there is condensate in the steam pipeline, it will be strongly impacted by the high-speed flowing steam on the pipe wall, valves, and steam equipment, causing damage or damage to the pipeline bends, valves, and steam equipment. (2) To prevent a decrease in the efficiency of steam using equipment: Steam using equipment (especially indirect heating devices) is aimed at effectively utilizing the latent heat of steam. Excessive condensate trapped in these devices comes into contact with the heating surface, reducing the heating area and uneven heating up and down, resulting in a significant decrease in equipment efficiency. (3) Prevent corrosion of steam inside equipment: Oxygen in water and air coming into contact with the equipment can cause chemical reactions, leading to rust corrosion. (4) Prevent damage to steam using equipment: Due to the different temperatures of steam and water, the condensed water inside the equipment generates temperature differences locally, causing temperature difference stress and equipment damage. Specific requirements for steam trap valves: (1) No steam leakage during the discharge of condensate; (2) It can eliminate all condensed water from any part of the steam system; (3) Capable of simultaneously discharging air and condensate; (4) Suitable for a wide range of pressures; (5) Easy to repair and maintain: simple structure with few moving parts; (6) High practicality: small size, light weight, long lifespan, low price, and no loss of emission capacity due to air and steam.

How to Prevent Damage to the Sealing Surface of High-pressure Ball Valves?
How to Prevent Damage to the Sealing Surface of High-pressure Ball Valves?
2024-04-12

In industrial production, high-pressure ball valves play a crucial role, and damage to the sealing surface may lead to leakage and performance degradation. Therefore, measures must be taken to prevent and protect the sealing surface. 1. Proper Operation and Usage When operating high-pressure ball valves, it is essential to follow the correct operating procedures and technical requirements. Do not exceed the rated pressure and temperature range of the valve. Avoid over-tightening the valve to prevent damage to the sealing surface or premature wear. 2. Regular Inspection and Maintenance Regularly inspect the sealing surface of the ball valve, especially valves exposed to high-pressure and high-temperature environments. Remove any debris and dirt around the valve to ensure the sealing surface is in good working condition. 3. Select Appropriate Sealing Materials Choose suitable sealing materials according to the requirements of the working environment. For instance, in high-temperature or chemically corrosive environments, select sealing materials that are resistant to high temperatures and corrosion. Regularly inspect the wear and aging of sealing materials and promptly replace damaged seals. 4. Preventing Foreign Object Intrusion Install filters or screens to prevent foreign objects from entering the valve body and damaging the sealing surface. Avoid conducting messy operations around high-pressure ball valves to reduce the intrusion of external impurities. 5. Timely Repair and Replacement If damage or wear is found on the sealing surface, stop using it immediately and proceed with repairing or replacing the seals to prevent leaks from causing more serious issues. 6. Training and Education Provide training to operators to ensure they understand the working principles and proper operation methods of high-pressure ball valves, reducing the risk of seal surface damage due to operational errors. 7. Minimize Frequent Opening and Closing Reduce the frequency of opening and closing high-pressure ball valves because frequent operation increases wear and fatigue on the sealing surface, leading to premature failure. Where possible, take measures to minimize valve cycling, such as planning production schedules rationally or employing automated control systems. 8. Regular Cleaning and Maintenance Perform regular cleaning and maintenance on high-pressure ball valves to remove accumulated dirt and deposits inside the valve body, ensuring the valve operates smoothly and the sealing surface remains clean. Regular cleaning effectively reduces contamination and corrosion of the sealing surface, extending the lifespan of the seals. 9. Choose High-Quality Ball Valves Select high-quality high-pressure ball valve products to ensure that the design and manufacturing quality of the valves meet standard requirements and possess excellent performance and reliable sealing capabilities. Valves from DERVOS typically offer longer lifespan and better sealing effects, effectively...

다섯 개의 백성 중 하나
加载中...

DN100 A516 배수 밸브가있는 도관 슬래브 게이트 밸브를 통해

DN100 도관 슬레이트 게이트 밸브를 통해 EN558.It 피깅 기능이 필요한 파이프 라인 애플리케이션에 이상적입니다.

  • 지불:

    30% when order confirmed, 70% before shipment
  • 제품 원산지:

    China
  • 색:

    Customization
  • 배송 포트:

    Shanghai, China
  • 리드 타임:

    30~60 days Ex Works after order confirmation
  • Material:

    A516
  • Method of Operation:

    Handwheel
지금 문의
제품 상세 정보

빠른 세부 사항

유형

게이트 밸브

공칭 직경

DN100

공칭 압력

PN63

구성

슬래브 유형; 통과 도관

연결

d 유형 플랜지

디자인 & 제조

EN558

끝에서 끝까지 차원

EN558.1

플랜지 치수

EN1092-1 디

테스트 & 검사

API598

바디 재질

A516

디스크 재료

A516

시트 재료

A105 + ENP + RPTFE

기온 범위

-29 ~ 121 ℃

미디어

물, 증기, 기름, etc

도관 플레이트 게이트 밸브를 통해 석유 및 가스 산업 액체 및 가스 응용 분야를위한 선택 where 신뢰할 수 있고 긴밀한 차단 누출을 방지하고 공정 오염 손실을 최소화하기 위해 필요합니다.

풍모

-화재 안전 레벨 : Mk

-온도. 레벨 : T3 ,

-누설 레벨 : EN12266A

-뒤로 좌석

-기본 금속 보조 부드러운 시트

-변경 가능 물건을 포장



기술 도면


증인 테스트


포장


특별 테스트

일반 테스트 외에도 (유압 및 공기 테스트) 할 수 있습니다 또한 인장 강도 시험, metallographic 테스트, 비산 배출 테스트, andNDE 테스트 (UT, RT, PT, MT) upon 고객 ' 특정 요청.



메시지를 남길

에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

관련 상품
탄소강 슬래브 게이트 밸브
플랜지 도관 슬래브 게이트 밸브 dn200 pn64를 통해

din 표준에 따라 설계된 관통 도관 슬래브 게이트 밸브에는 파이프 라인 청소를위한 전환 구멍이 있습니다. pn64 병렬 디스크 게이트 밸브는 rf 플랜지와 핸드 휠이있는 탄소강으로 만들어집니다. 빠른 세부 사항 유형 평행   슬래브 게이트 밸브 공칭 직경 dn   200 공칭 압력 pn   64 구성 평행   슬래브 게이트 밸브, 전환 구멍 있음, 볼트 식 보닛, 탄성 시트 연결 플랜지 조작 핸드 휠   조작 바디 재료 탄소   강철 매질 물,   석유와 가스 유래 중국 디자인 기능1. 파렐 디스크선택을위한 2.soft 좌석 그리고 금속 좌석pigging와 더 적은 압력 강하를위한 3.full 구멍 디자인4. 화재 안전 설계5.self 구호 기능좌석과 줄기를위한 6.Grease 이음쇠7. 더블 블록 및 블리드 기능8. 배기 및 배수 포트9. 꽉 밀봉 성능 재료 부품 이름 재료 몸 & amp; 보닛 a216 wcb, cf8, cf8m, cf3,   cf3m 쐐기 합금강 (표면 경화   처리), 스테인리스 스틸 (공동 오버레이 포함) 줄기 합금강 (면   침식 방지 처리) 좌석 합금강 (표면 경화   처리, 베셋 f 플라스틱), 스틸 (공동 오버레이, 최고 f 플라스틱) 포장 ptfe O 링 nbr, p 밀봉 그리스 & emsp;

도관 게이트 밸브를 통해
도관 확장 게이트 밸브를 통해 18 인치 600lb api6d

도관 게이트 밸브를 통한 API 6d는 이중 확장 웨지, 금속 대 금속 시트 및 피깅을위한 전환 구멍으로 설계되었습니다. 밸브는 밀봉 성능이 우수하고 유동 저항이 적으며 일부 고체 또는 입자와 함께 사용하기에 적합합니다. 빠른 세부 사항 유형 문   판막 크기 18 인치 설계 압력 아니   600 구성 더블   쐐기, 완전 금속 시트, 전환 구멍 있음 연결 타입 rtj   플랜지 작업 유형 변속 장치   움직이는 바디 재료 wcb 쐐기 a105 + stl + enp 줄기 재료 17-4ph 시트 재료 a105 + stl + enp 디자인 코드 API 6D 대면 치수 저 같은   b16.10 연결 종료 저 같은   b16.5 압력 및 온도 저 같은   b16.34 매질 물,   석유와 가스 유래 중국

게이트 밸브
API 6D 스루 도관 게이트 밸브 소프트 시트 20인치 600LB

API 6D 스루 도관 게이트 밸브는 탄소강 WCB로 만든 600LB 플랜지 및 기어박스 연결.로 설계되었습니다., 20인치 게이트 밸브는 전환 구멍이 없는 부드러운 시트 설계를 가지고 있습니다..

볼 밸브
10" 300LB 트러니언 장착형 볼 밸브 RF WCB API6D 터빈

10" 300LB 볼 밸브는 API 6D 표준에 따라 제작되었습니다. 밸브 본체는 ASTM A216 WCB로 제작되었습니다. 풀 보어, 고정 볼, 화재 방지, 정전기 방지 및 비행 방지 밸브 스템 설계의 구조적 특성을 가지고 있습니다. 연결 모드는 RF이며 터빈 작동 모드가 있습니다.

다섯 개의 백성 중 하나
wcb 게이트 밸브 pn25 dn250 볼트 보닛 rf

dn250 pn25 게이트 밸브는 din 3352에 따라 설계되었습니다. 볼트로 고정 된 보닛, 외부 요크 및 핸드 휠과 같은 밸브의 공통 부분이있는 몸체는 wcb 및 stl로 만들어집니다. 밸브 본체, 보닛, 시트 및 기타 부품을 추적 할 수 있습니다.

배기 밸브
DN80 PN10 배기 밸브 EN1092-1 QT450 CJ/T217-2005

DN80 PN10 배기 밸브는 CJ/T217-2005 표준에 따라 제작되었습니다. 밸브 본체는 QT450으로 제작되었습니다. 연결 모드는 EN1092-1입니다.

다섯 개의 백성 중 하나
DIN 단일 플레이트 웨이퍼 체크 밸브 DN80 PN40

The 단일 디스크 CF8로 만든 체크 밸브는 내식성이 우수합니다. 에 따라 설계됨 API594, 밸브는 웨이퍼 유형입니다.

주철 비 상승 줄기 게이트 밸브
무쇠 비 상승 줄기 게이트 밸브 rf dn80 pn16

dn80 pn16 주철 게이트 밸브는 din3202 f4 또는 din3202 f5에 따라 대면 치수를 갖습니다. 이 gg25 게이트 밸브는 수처리 용도에 적합한 탄성 시트, 비 상승 스템, bb, rf 플랜지로 설계되었습니다. 빠른 세부 사항 유형 문   판막 공칭 직경 dn   80 공칭 압력 pn   16 건축 유형 비 상승   줄기, 볼트 형 보닛, 탄성 시트 연결 타입 플랜지 작업 유형 핸드 휠   조작 바디 재료 캐스트   철 gg25 트림 재료 주철 웨지, ss420 스템,   epdm 좌석 디자인 코드 식사 3352 엔드 투 엔드 코드 식사 3202 플랜지 치수 딘 2501 매질 물 유래 중국 디자인 기능 좋은 밀봉 성과를위한 1.resilient 좌석 2. 낮은 흐름 저항과 작은 압력 강하 3. 설치 공간에 대한 비 상승 줄기가 제한됩니다 매체의 흐름 방향에 대한 4.No 제한 반대로 부식성 기능을위한 벨브의 내부와 외부 부분을 위해 유효한 5.epoxy 회화 회사 소개 10 년 이상 밸브 산업을 전문으로하는 dervos는 게이트, 글로브, 체크, 볼, 버터 플라이, 플러그 밸브 및 스트레이너의 주요 공급 업체가되었습니다. 우리는 현지 파트너와 함께 lukoil, mol, ypf와 같은 석유 및 가스 사용자에게 서비스를 제공합니다. dervos의 장점은 다음과 같습니다. 1. 수십 개의 안정적인 공급 업체와의 파트너십을 통해 고객에게 다양한 고품질 제품을 경쟁력있는 가격으로 제공 할 수 있습니다. 2. 각 주문 배달 전에 검사 보고서와 엄격한 품질 관리. 3. 우리는 고객이하는만큼 배달 시간을 중요하게 생각합니다. 강력한 구매 시스템을 통해 각 주문을 밀접하게 준수하여 정시 배송을 보장합니다. 4. 원 스톱 솔루션은 적시에 제공됩니다

볼 밸브
1-1/2" 150LB 라이닝 볼 밸브 FF CF8+PFA 레버 GB/T12237-2007

1-1/2" 150LB 볼 밸브는 GB/T12237-2007 표준에 따라 제작되었습니다. 밸브 본체는 CF8+PFA로 제작되었습니다. 불소 라이닝의 구조적 특성을 가지고 있습니다. 연결 모드는 FF입니다. 그리고 레버 작동이 있습니다. 방법.

게이트 밸브
3/4" 150LB 단조 강철 게이트 밸브 RF F316L API602 수동 핸들

3/4" 150LB 게이트 밸브는 API 602 표준에 따라 만들어집니다. 밸브 본체는 ASTM A182 F316L로 만들어집니다. 볼트 커버, 상승 줄기 및 단단한 쐐기의 구조적 특성을 가지고 있습니다. 연결 모드는 RF 일체형 플랜지입니다. 그리고 그것은 핸드 휠 작동 모드가 있습니다.

웨이퍼 체크 밸브
CF8M 20" 150LB 듀얼 플레이트 웨이퍼 체크 밸브 API594

20" 150LB 웨이퍼 체크 밸브는 API594 표준에 따라 만들어집니다. 밸브 본체는 A351 CF8M으로 만들어집니다. 이중 플레이트 및 내장형 구조적 특징을 가지고 있습니다. 연결 모드는 웨이퍼 RF입니다.

다섯 개의 백성 중 하나
3 조각 위치 유형 볼 밸브, ASTM A105N, Class 800, 1 인치

중국 탄소강 볼 밸브 제공 업체는 3 개 위치 유형 볼 밸브를 제공합니다. ASTM A105N, 클래스 800, 1 인치, 무료 플로팅 볼, API 608, BS 5351.

메시지를 남겨주세요

    에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

제품

접촉