Analysis of Valve Sealing Surface Damage Causes
Analysis of Valve Sealing Surface Damage Causes
2026-01-23

Damage to valve sealing surfaces is typically the result of multiple contributing factors, including material selection, operating conditions, operating practices, and maintenance. The following is a categorized summary of the most common causes:   1. Mechanical Damage ●  Wear: Solid particles in the medium (such as sand or welding slag) erode the sealing surface, resulting in scratches or grooves. ●  Abrasive scuffing: Frictional wear caused by relative movement of the sealing surfaces during valve opening and closing, particularly in metal-to-metal sealing pairs. ●  Impact damage: Deformation of the sealing surface caused by high-velocity fluid impingement or rapid valve opening and closing, leading to impact loading.   2. Chemical Corrosion ● Media corrosion: Acidic, alkaline, or oxidizing media directly attack the sealing surface material, such as metal corrosion caused by H₂S or chloride ions. ● Electrochemical corrosion: When sealing pairs made of dissimilar metals are exposed to an electrolyte, galvanic corrosion may occur due to electrochemical cell formation. ● Erosion–corrosion: The combined effect of corrosive media and high-velocity flow accelerates material loss on the sealing surface.   3. Thermal Damage ●Thermal fatigue:Frequent temperature fluctuations cause repeated thermal expansion and contraction of the sealing surface, leading to cracking or deformation. ●High-temperature oxidation:At elevated temperatures, the sealing surface may undergo oxidation, hardening, or burn-off, as commonly observed in steam valve applications. ●Thermal shock:Sudden exposure to high- or low-temperature media can cause cracking of the sealing surface, such as during rapid condensation or cold media ingress.   4. Improper Installation and Operation ●Installation misalignment: Incorrect valve installation or excessive piping stress can result in uneven loading on the sealing surfaces. ●Over-tightening: Excessive preload applied to the valve stem or bolting may crush or deform the sealing surface, particularly in soft-seated valves or soft sealing gaskets. ●Rough operation: Rapid opening and closing or excessive operating force can cause impact damage to the sealing surfaces.   5. Material Defects ●Improper material selection: The sealing surface material lacks sufficient resistance to process media, high temperature, or wear, such as the use of carbon steel in acidic service. ●Manufacturing defects: Defects in the hardfacing or overlay layer, including porosity, slag inclusions, or improper heat treatment, reduce wear resistance and overall sealing performance.   6. Abnormal Operating Conditions ●Cavitation / flashing: Pressure fluctuations in the fluid generate vapor bubbles that collapse and impact the sealing surface, a phenomenon commonly observed in valves installed downstream of pumps. ●Scaling / deposition: Impurities in the medium accumulate on the sealing surface, impairing tight shutoff, suc...

2025년 데르보스 팀빌딩 여행: 광시에서 산과 바다를 넘나드는 여정
2025년 데르보스 팀빌딩 여행: 광시에서 산과 바다를 넘나드는 여정
2026-01-16

2025년, 데르보스는 연례 팀 여행을 기획하여 광시성 충쭤, 웨이저우 섬, 난닝으로 5일간의 여정을 떠났습니다. 이번 여행은 휴식을 제공하고 팀원 간의 소통을 강화하는 것을 목표로 했으며, 자연 경관과 현지 문화 체험을 조화롭게 결합한 알찬 프로그램을 제공했습니다. In Chongzuo, the team focused on nature sightseeing. Bamboo rafting tours allowed close observation of the local ecology and offered opportunities to see rare species such as the white-headed leaf monkey. The group also visited Detian Waterfall, experiencing its scale and flow firsthand. The overall itinerary was designed with a relaxed pace, providing ample time for rest and team bonding. Next, the team traveled to Weizhou Island. The volcanic landforms and coastal scenery added a unique visual dimension to the journey. Beyond sightseeing, participants engaged in local agricultural activities, including dragon fruit picking and banana harvesting, gaining insight into local lifestyles. The team also visited several beaches, fully appreciating the island environment. The final stop was Nanning. Team members explored the night market, sampled local specialties, and experienced the city’s daily life, bringing the Guangxi trip to a relaxed conclusion. This annual trip allowed the Dervos team to foster more natural communication and connection outside of work, recharging energy for the months ahead. Dervos remains committed to its guiding principle: I come, I see, I conquer!

밸브 진동 및 소음 문제 해결 가이드
밸브 진동 및 소음 문제 해결 가이드
2026-01-06

이러한 증상은 일반적으로 체액 상태의 불일치를 나타냅니다. valve selection, or system configuration. If left unaddressed over prolonged operation, they can accelerate valve wear and pose safety risks. Based on field experience, this article outlines the common causes of valve vibration and noise and provides practical guidance for troubleshooting. 1. Basic Manifestations of Valve Vibration and Noise Valve vibration usually appears as noticeable oscillations of the valve body, stem, or connected piping. Noise may present as humming, whistling, or banging sounds. These phenomena often occur simultaneously and are primarily related to the following factors: ● Abnormal flow velocity or pressure differential ● Unstable internal forces within the valve ● Mismatch between actual operating conditions and valve design 2. Common Causes Analysis 1. Excessive Flow Velocity or Pressure Differential When the fluid passes through the throttling section of a valve at high speed, strong turbulence and pressure fluctuations are likely to occur, causing periodic impact on internal components. This issue is particularly pronounced when using standard globe valve s or ball valves under regulating conditions. Typical manifestations include: ● Noise increases as the valve opening decreases ● Vibration intensifies under high-pressure-drop conditions 2. Improper Valve Selection Incorrect valve selection is a common root cause of vibration, such as: ● Using on/off valves for prolonged throttling ● Oversized valve operating at small openings for extended periods ● Insufficient pressure rating or structural rigidity of the valve These conditions can cause unstable movement of the valve plug or ball, resulting in vibration and noise. 3. Loose or Worn Internal Components After long-term operation, the following issues are commonly observed: ● Wear of valve plugs or discs ● Increased clearance between the stem and guiding parts ● Loosened fasteners Non-design clearances amplify fluid impact, leading to persistent noise. If vibration is accompanied by metallic knocking sounds, the condition of internal components should be checked as a priority. 4. Cavitation or Flashing In liquid service, cavitation or flashing occurs when local pressure drops below the saturation vapor pressure. Bubble collapse in high-pressure regions impacts internal components, often accompanied by noise and vibration. Typical signs include: ● Sand- or gravel-like scraping sounds ● Rapid wear of internal components ● Significant pressure fluctuations 5. Insufficient Piping Support or System Resonance Some vibrations are not directly caused by the valve. When upstream or downstream piping lacks adequate support, or when the piping structure resonates near the fluid pulsation frequency, system resonance may occur, amplifying existing vibrations. 3. On-Site Troubleshooting Approach It is recommended to follow the sequence below when troubleshooting: ● Verify whether the pressure, flow rate, and fluid are within the design limits ● Che...

글로브 밸브
加载中...

1/2" 800LB 단조 강철 글로브 밸브 SW F316/316L API602 핸드 휠

1/2" 800LB 글로브 밸브는 API 602 표준에 따라 만들어집니다. 밸브 본체는 ASTM A182 F316/F316L+STL로 만들어집니다. 볼트 커버, 디스크 스위블 플러그, 바디 시트 및 OS&Y의 구조적 특성을 가지고 있습니다. 연결 모드 SW 이며 핸드 휠 작동 모드가 있습니다.

  • 지불:

    30% when order confirmed, 70% before shipment
  • 제품 원산지:

    China
  • 색:

    Customization
  • 배송 포트:

    Shanghai, China
  • 리드 타임:

    30~60 days Ex Works after order confirmation
  • Material:

    ASTM A182 F316/F316L+STL
  • Method of Operation:

    Hand Wheel
지금 문의
제품 상세 정보

제품 설명

유형

글로브 밸브

크기

1/2"

압력

800파운드

연결

남서

작업

핸드 휠

본체 재질

ASTM A182 F316/F316L+STL

디자인 규범

API 602

면간 치수

제조업체의 표준.

SW 치수

ANSI B16.11

테스트 및 검사 코드

API STD.598

온도

-29 ~ 300°C

적용 가능한 매체

물, 석유 및 가스

특징

1. 광범위한 압력 및 온도에 적합합니다.

2. 우수한 밀봉 성능으로 긁히거나 착용하기 쉽지 않습니다.

기술 도면

치수 확인

압력 테스트

명판 및 포장

검사 보고서

메시지를 남길

에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

관련 상품
단조 스틸 ASTM A105 글로브 밸브
단조 스틸 글로브 밸브 1 인치 800lb 스레드 매뉴얼

1 인치 800lb 암나사 형 글로브 밸브에는 플러그 디스크, 포트 감소 및 수동 핸드 휠 작동이 있습니다. 밸브는 api 602에 따라 a105n 바디와 트림 5로 제작됩니다. 빠른 세부 사항 유형 지구   판막 크기 1'' 압력 수업   800 구성 볼트   보닛, 감소 된 포트, 외부 scew & amp; 멍에 연결 타입 npt   암나사 작업 유형 핸드 휠   움직이는 디자인 코드 API   602 끝으로 종료   치수 저 같은   b16.10 연결 저 같은   b1.20.1 압력 및   온도 저 같은   b16.34 테스트 & amp;   검사 API   598 바디 재료 서서히 나아가는   스틸 a105 트림 재료 13cr + 위성 온도 범위 -29 ℃ ~ + 427 ℃ 신청 물,   석유 가스 유래 중국 제품 범위4 인치까지 1.size150lb에서 2500lb 사이의 2.design 압력3. 연결 : 플랜지, 소켓 용접, 스레드4.operation : 액추에이터와 더불어 수동 핸들, 변속기, 벌거 벗은 줄기,5.body 물자 : 탄소 강철, 스테인리스, 합금 강철6.trim 재질 : 트림 1, 5, 8, 10, 12, 16 등.7. 볼트 보닛, 압력 밀봉 보닛, 용접 보닛, 스크류 보닛8. 감소 구멍, 전체 구멍 검사 보고서각 주문과 함께 dervos는 선적 후 검사 보고서와 재료 테스트 보고서를 무료로 제공합니다. 이러한 모든 인증서를 통해 검사 프로세스 및 결과를 명확하게 파악할 수 있습니다. 또한이 보고서는 추적 성을 위해 사용될 수 있습니다.

단조 스틸 글로브 밸브
단조 스틸 글로브 밸브 스트레이트 SDNR FNPT

역류 방지 설계의 글로브 밸브는 개방 위치에 있을 때 역류를 방지하며 격리 작업에도 적합합니다. 수동으로 작동하며 핸드휠과 함께 제공됩니다.

티 패턴 글로브 밸브
DN25 PN250 티 패턴 글로브 밸브 단조 스틸 API 602

빠른 세부 정보 유형 글로브 밸브DN DN50PN PN250 건설 티 패턴; 볼트 보닛; 연결 타입 NPT 작업 유형 핸드휠 디자인 코드 API602 나사 끝 ASME/ANSI B1.20.1 테스트 & 검사 API598 본체 재질 A105+STL 트림 소재 A276-420 중간 물, 석유 및 가스 기원 중국 특징 -- 글로브 밸브에는 스로틀링 및 차단 기능이 모두 있습니다. -- 유지 보수가 용이하고 좌석을 다시 표면 처리합니다. -- 디스크가 스템에 부착되지 않은 경우 스톱 체크 밸브로 사용 가능 기술 도면 치수 확인 증인 시험 더보스 패키징 좋은 포장은 좋은 첫인상을 의미합니다. 아래 두 개의 상자를 보면 어떤 느낌이 다를지 상상해 보세요. 그리고 Dervos에서 포장을 그토록 중요시하는 이유를 알게 될 것입니다. Dervos에서는 다음을 확인합니다. 모든 밸브는 깨끗하고 건조합니다. - 포장하기 전에 밸브를 청소하십시오. - 방청유 첨가 - 플랜지 커버 추가 배송 시 밸브에 손상이 없습니다. - 철선으로 밸브 고정 - 부드러운 재질로 밸브를 분리 - 합판으로 밸브를 겹칩니다. - 튼튼한 상자와 명확한 배송 표시

글로브 밸브
단조 스틸 글로브 밸브 DN15 ASA2500 NPT

외부 나사 및 요크, 핸드휠 작동, NPT가 있는 단조 스틸 글로브 밸브는 A105로 만들어졌으며 BS5352에 따라 설계되었습니다.

글로브 밸브
11/2" 800LB 단조 강철 글로브 밸브 SW A105 API602

11/2" 800LB 글로브 밸브는 API602 규격에 따라 제작되었습니다. 밸브 본체는 A105+STL로 제작되었습니다. 용접 보닛의 구조적 특성을 가지고 있습니다. 연결 모드는 SW이며 핸드 휠 작동 모드가 있습니다.

글로브 밸브
3/4" 800LB 단조 강철 글로브 밸브 SW+FNPT A105N API602

3/4" 800LB 글로브 밸브는 API 602 표준에 따라 만들어집니다. 밸브 본체는 A105N+ STL로 만들어집니다. 플러그, 디스크 스위블 플러그, 바디 시트 및 OS&Y의 구조적 특성을 가지고 있습니다. 연결 모드는 SW+FNPT입니다. 그리고 핸드 휠 작동 모드가 있습니다.

글로브 밸브
DN25 PN63 단조 강철 글로브 밸브 BS5352 핸드휠 A105N SS304

DN25 PN63 글로브 밸브는 BS5352 표준에 따라 제작되었습니다. 밸브 본체는 A105N+SS304로 만들어집니다. 볼트커버의 구조적 특성을 지닌 Straight Through Type입니다. 연결 모드는 EN1092-1 D입니다. 그리고 핸드 휠 작동 모드가 있습니다.

글로브 밸브
DN25 PN100 단조 강철 글로브 밸브 A105N SS304 API602

DN25 PN100 글로브 밸브는 API 602 표준에 따라 제작되었습니다. 밸브 본체는 A105N+SS304로 만들어집니다. 볼트커버의 구조적 특성을 지닌 Straight Through Type입니다. 연결 모드는 EN1092-1 D입니다. 그리고 핸드 휠 작동 모드가 있습니다.

글로브 밸브
API602 1/2" 150LB 단조 강철 글로브 밸브 A105N RF 핸드휠

1/2" 150LB 글로브 밸브는 API 602 표준에 따라 제작되었습니다. 밸브 몸체는 ASTM A105N+STL로 제작되었습니다. 관통형의 구조적 특성을 가지고 있습니다. 연결 모드는 RF이며 핸드 휠 작동 모드가 있습니다. .

글로브 밸브
단조 강철 글로브 밸브, RF 연결, 1/2'' 150LB, 본체 A105N, API602

1/2" 150LB 글로브 밸브는 API 602 표준에 따라 제작되었습니다. 밸브 몸체는 ASTM A105N+STL로 제작되었습니다. 관통형의 구조적 특성을 가지고 있습니다. 연결 모드는 RF이며 핸드 휠 작동 모드가 있습니다. .

글로브 밸브
RF 연결, 단조 강철 글로브 밸브, 1'' 600LB, 본체 A105N, API602

1" 600LB 글로브 밸브는 API 602 표준에 따라 제작되었습니다. 밸브 본체는 ASTM A105N+STL로 제작되었습니다. 볼트 커버의 구조적 특성을 지닌 직선 관통형입니다. 연결 모드는 RF입니다. 그리고 핸드 휠 작동 모드가 있습니다. .

글로브 밸브
DN25 PN40 단조 강철 글로브 밸브, EN1092-1 B 연결, 본체 F316, BS5352

DN25 PN40 단조 강철 글로브 밸브는 BS 5352 표준에 따라 제작되었습니다. 밸브 몸체는 A182-F316+STL로 만들어졌습니다. 볼트커버와 스트레이트형의 구조적 특징을 가지고 있습니다. 연결 모드는 EN1092-1 B입니다. 그리고 핸드 휠 작동 모드가 있습니다.

메시지를 남겨주세요

    에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

제품