한국의

한국의

Get a Quote
제품

핫 제품

회사 뉴스

Installation of Large Diameter Ball Valves
Installation of Large Diameter Ball Valves
2026-03-09

Large diameter ball valves are commonly used in industries such as petroleum and chemical processing, power generation, long-distance pipeline transportation, and large-scale water treatment systems. If installation is not performed correctly, it may lead to sealing leakage, valve jamming, or structural stress damage. Therefore, proper installation practices are essential to ensure long-term stable operation.   1. Pre-installation Inspection   If pre-installation inspection is insufficient, operational failures are more likely to occur during service. First, inspect the valve body for transportation damage. If scratches, impact marks, or deformation are found on the valve body or sealing surfaces, installation should be stopped and the supplier should be contacted.   Next, verify valve model, pressure rating, and connection standards. If the system design pressure does not match the valve pressure class, operational safety risks may occur. For example, if a low-pressure class valve is mistakenly used in a high-pressure pipeline system, the valve body may experience plastic deformation under water hammer impact.   It is also necessary to check the condition of the ball surface and sealing rings. If there are scratches on the ball surface, sealing performance will be reduced. This is especially critical in gas transmission systems where micro-leakage is more likely.   2. Installation Direction   Large diameter ball valves usually have a flow direction marking. If the installation direction is incorrect, the following problems may occur: If the fluid flow direction matches the design direction, the operating torque will remain more stable. If the valve is installed in reverse, the stem may experience increased mechanical load, which will accelerate stem wear during long-term operation. For double-seal bidirectional ball valves, although bidirectional flow is allowed, installation according to the marked flow direction is still recommended to ensure more uniform sealing stress distribution. In high-temperature or steam systems, if the installation direction is incorrect, thermal expansion may accelerate sealing ring aging.   3. Pipeline Stress Control   Large diameter ball valves are heavy. If installed without proper support, additional bending moments may be transferred to flange connections. If pipeline systems experience axial displacement, pipeline supports should be installed for segmented fixation. If support structures are not provided, the valve body may bear long-term gravitational tensile load, eventually causing flange seal failure. It is generally recommended to install independent supports on both sides of large diameter ball valves. If the pipeline system is subject to thermal expansion and contraction, expansion compensation devices must be installed; otherwise, sealing surfaces may gradually fail.   4. Bolt Tightening Process   Flange connections of large diameter ball valves usually ...

Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
2026-03-02

This year’s Dervos annual conference was noticeably more grand and well-organized than in previous years.   In the morning session, each department delivered its annual work summary, reviewing key projects and achievements over the past year. Teams also openly shared the challenges encountered during implementation and the practical experience gained along the way.   Through this cross-department exchange, everyone developed a clearer understanding of one another’s responsibilities and workflows, laying a stronger foundation for future collaboration and communication.     In the afternoon session, the Outstanding Employee awards were presented. Each nominee shared their work achievements and practical experience, demonstrating a strong sense of responsibility and execution across different roles. It is precisely this proactive mindset, collaborative spirit, and down-to-earth working approach of Dervos employees that drives the team steadily toward its shared goals.     Showing up on time every single day throughout the year — that’s quite an achievement. Ian has now received the Perfect Attendance Award for two consecutive years.     During the annual conference, Dervos also presented medals and exclusive commemorative gifts to employees who have completed five years of service.     Dervos values the long-term dedication and consistent commitment of its team members, and sincerely appreciates the trust and contributions they have made over the years. For many at Dervos, the company is not only a platform for professional growth, but also a stage where shared goals and collective efforts come to life. In the evening, the annual conference transitioned into the banquet segment. Performances and interactive games were seamlessly interspersed, creating a relaxed yet organized atmosphere.     Laughter and cheers echoed throughout the venue, and in the moment the camera shutter clicked, the excitement and joy were captured in a single frame.     Eric said: "Let’s dream together, DERVOS's dream. A dream where we all play a part, piece by piece, it becomes a reality." For Dervos, the annual meeting is not just about "summarizing the year," but about bringing our hearts together, strengthening our resolve in doing the same thing, and then continuing to move forward, step by step, with steady progress.            

What Is the Difference Between Plug Valves and Ball Valves?
What Is the Difference Between Plug Valves and Ball Valves?
2026-02-20

Ball valves and plug valves differ significantly in several aspects, including structure, operating principle, mode of operation, flow control capability, sealing performance, and application scenarios. These differences enable the two types of valves to perform distinct roles in their respective fields.   Structural Differences   The ball valve, a design evolved from the plug valve, utilizes a spherical element as its core component. By rotating the ball 90° around the stem axis, the valve can be opened or closed. Its structure is straightforward, consisting primarily of a spherical closure element with a through-bore housed within the valve body.   In contrast, the structure of a plug valve is more complex. It comprises multiple components such as the valve body, bonnet, plug, seat, and stem. The closure element is a cylindrical or tapered plug that controls flow by rotating 90°, aligning or misaligning the port in the plug with the flow passage in the valve body to achieve opening or shutoff.   Operating Principle   The operating principle of a ball valve relies on the rotation of the ball to control the on-off flow of fluid. When the ball is in tight contact with the valve seat, the clearance between them is completely sealed, thereby preventing fluid leakage. When the ball rotates to a position disengaged from the seat, the fluid is allowed to flow freely through the passage inside the valve body.   The operating principle of a plug valve differs in that it primarily controls the flow passage by rotating the plug element to open or close the valve. In a plug valve, the plug is connected to the stem and rotates together with it to achieve flow control. The closure element is a tapered plug with a port, and the flow passage is designed to be perpendicular to the axis of the plug. This configuration enables the plug valve to operate more efficiently and reliably during opening and closing.   The operation of a ball valve is notably simple, requiring only a 90-degree rotation to achieve opening or closing. This design allows the flow passage to be opened or shut off quickly and smoothly when the ball is rotated by 90 degrees, providing both convenience and efficiency. In addition, ball valves offer relatively low flow resistance in the fully open or fully closed position, making them particularly suitable for applications that require rapid on-off operation.   By contrast, the operation of a plug valve is comparatively more complex, as several turns are typically required to complete the opening or closing action. The valve plug is designed in a cylindrical or tapered form and regulates fluid flow through rotation. Nevertheless, plug valves demonstrate excellent performance in flow regulation, enabling precise adjustment of the flow passage diameter and accurate control of flow rate. However, due to the relatively complicated operating process, plug valves are not well suited for frequent operation...

라인 블라인드 밸브
加载中...

DN50 CL150 고온 캠 슬라이드 라인 블라인드 밸브 스테인레스 스틸

라인 블라인드 밸브는 수동, 전기 또는 공압 또는 유압으로 가스 매체를 차단하는 일종의 게이트 밸브입니다. 일반적으로 전기 블라인드 밸브, 유압 블라인드 밸브, 폐쇄 플러그 밸브 및 전기 개방형 블라인드 밸브로 나뉩니다.

  • 지불:

    30% when order confirmed, 70% before shipment
  • 제품 원산지:

    China
  • 색:

    Customization
  • 배송 포트:

    Shanghai, China
  • 리드 타임:

    30~60 days Ex Works after order confirmation
지금 문의
제품 상세 정보

제품 설명

고온 캠슬라이드는 라인 블라인드 밸브의 특수 유형으로 고온 저항 기능이 일반 블라인드 플랜지 밸브와 크게 다릅니다. 일반 라인 블라인드 밸브는 일반적으로 온도가 0°C ~ 200°C인 매체에 적합하며 고온 캠 슬라이드 라인 블라인드 밸브는 일반적으로 온도가 200°C 이상인 고온 환경에서 사용할 수 있습니다. 800°C의 고온에서도 견딜 수 있습니다.

특징

1. 고온 환경에서 사용할 수 있으며 일반적으로 200℃ 이상의 응용 분야에 적합하며 800℃까지 견딜 수 있습니다.

2. 컴팩트한 디자인으로 공간 제약이 있는 환경에서도 사용이 가능합니다.

3. 조작이 간단하고 편리하며 손잡이만 있으면 스위치가 완성됩니다.

4. 밸브 본체는 일반적으로 스테인리스 스틸 또는 기타 내부식성 재질로 제작되어 열악한 화학 환경에서 사용하기에 적합합니다.

5. 밀봉 성능이 우수하여 매체 누출을 효과적으로 방지합니다.

기술 도면

라인 블라인드 밸브 기술 사양

설명

기준

공칭 직경

1/2"(DN15) ~ 24"(DN600)

온도 범위

-20°C ~ 816°C(14°F ~ 1500°F)

압력 등급

요청 시 ASME 클래스 150 ~ 600 이상

작동 방식

수동, 공압식, 유압식, 전기식

재료

바디: HT 카본 또는 스테인리스 스틸

플레이트: 스테인레스 스틸

벨로우즈: 스테인레스 스틸

라인 블라인드 밸브 엔지니어링 표준

ASME 표준

설명

B16.5

파이프 플랜지 및 플랜지 피팅

B16.34

밸브 - 플랜지형, 나사산형 및 용접 끝단

B31.1

동력배관

ASME B&PV 코드

설명(보일러 및 압력 용기 코드)

섹션 II

재료

섹션 VIII

압력 용기 구성 규칙

섹션 IX

용접 및 브레이징 자격

API 표준

설명

API 598

밸브 검사 및 테스트

API 2217

석유 산업의 밀폐 공간 작업 지침

기타

설명

ISO 9001

품질 관리 시스템

NACE MR0175

황화물 응력 균열 및 응력 부식

메시지를 남길

에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

관련 상품
라인 블라인드 밸브
8" 클래스 150# 라인 블라인드 밸브 ASME DIN ISO 탄소강

라인 블라인드 밸브(안경 밸브)는 가스 매체를 수동, 전기 또는 공압 또는 유압으로 차단하는 일종의 게이트 밸브입니다. 일반적으로 전기 블라인드 밸브, 유압 블라인드 밸브, 폐쇄 플러그 밸브 및 전기 개방형 블라인드 밸브로 나뉩니다.

라인 블라인드 밸브
1" - 60" 클래스 150 - 2500 라인 블라인드 밸브 ASME B16.34

라인 블라인드는 상당한 압력 강하 없이 완전한 폐쇄 또는 방해 없는 흐름 전환이 필요할 때 파이프라인 시스템에 활용됩니다. THD(Through-Hole Design)를 통해 위치를 신속하고 원활하게 조정할 수 있습니다. THD 슬라이드 변형은 다중 볼트 구성을 자랑하므로 대면 치수가 줄어들어 작동이 더 쉬워집니다. 추가 본체 볼트가 포함되어 있어 이 스타일은 특히 고압 응용 분야에 적합합니다.

ASME B16.34 10 150LB 라인 블라인드 밸브, RF 연결, 본체 A105, 터빈
ASME B16.34 10" 150LB 라인 블라인드 밸브, RF 연결, 본체 A105, 터빈 작동

10" 150LB 라인 블라인드 밸브는 ASME B16.34 표준에 따라 제작되었습니다. 밸브 본체는 A105로 제작되었습니다. 적하 방지 구조적 특성을 가지고 있습니다. 연결 모드는 RF이며 터빈 작동 모드가 있습니다.

다섯 개의 백성 중 하나
DIN DN125 PN16 스테인레스 스틸 게이트 밸브 HW-OP BB RF

DN125 PN16 게이트 밸브는 DIN에 따라 제작됩니다. 3352 표준. 밸브 몸체는 1.4408로 만들어졌습니다. 그것은 구조적 SS316을 사용한 볼트 커버, 라이징 스템, 탄성 웨지의 특성 절연 재킷 및 구조 길이 325mm. 연결 모드는 RF입니다. EN1092-1 B1. 그리고 핸드 휠 작동 모드가 있습니다.

웨이퍼 체크 밸브
API594, 본체 F316, 2" 300LB 이중 플레이트 웨이퍼 유형 체크 밸브, RF

2" 300LB 이중 플레이트 웨이퍼 체크 밸브는 다음과 같습니다. API 594 표준에 따라 제작되었습니다. 밸브 몸체는 A182 F316으로 만들어졌습니다. 그것은 가지고있다 더블 디스크의 구조적 특성. 연결 모드는 RF입니다.

스윙 체크 밸브
2인치 CL800 스윙 체크 밸브 A105 API602 BSP

2인치 CL800 스윙 체크 밸브는 API602 표준에 따라 제작되었습니다. 밸브 본체는 A105 재질이며, BC의 구조적 특성을 가지고 있습니다. 연결 방식은 BSP입니다.

트러 니언 장착 볼 밸브
트러 니언 장착 DN300 PN63 DBB 볼 밸브

트러 니언 장착 볼 밸브 dn300 pn63 풀 보어 더블 블록 및 블리드 pmss 씰 (메탈 씰 + 소프트 씰) lf2 바디, lf2 + enp 볼 / 시트 및 410 스템으로 블로우 아웃 방지 스템 기어 박스 작동. 빠른 세부 사항 유형 볼 밸브 크기 dn300 설계 압력 pn63 구성 dbb, 트러 니언 장착 볼 밸브 연결 타입 플랜지 작업 유형 기어 박스 작동 바디 재료 lf2 볼 재료 lf2 + enp 줄기 재료 410 시트 재료 lf2 + enp 디자인 코드 API 6D 대면 치수 API 6D 연결 종료 asme b16.5 압력 및 온도 asme b16.34 매질 물, 기름 및 가스 유래 중국

 연성 철 게이트 밸브
연성 철 게이트 밸브 비 상승 줄기 pn10 ggg50

연성 철 게이트 밸브에는 ggg50 바디 재질과 epdm 소프트 시트가 있습니다. 밸브는 비 상승 스템, rf 연결 및 수동 작동으로 설계되어 화수에 사용됩니다. 빠른 세부 사항 유형 문   판막 크기 dn300,   dn400 설계 압력 pn10 구성 비 상승   줄기, 연약한 좌석 연결 타입 플랜지 작업 유형 핸드 휠   조작 바디 재료 ggg50 트림 재료 줄기 2cr13, epdm 좌석 매질 물 유래 중국 정수압 시험 치수 확인 포장

윤활 플러그 밸브
1" 3000PSI 윤활 플러그 밸브 NPT A105 API6D 레버

1" 3000PSI 윤활 플러그 밸브는 API6D 표준에 따라 제작되었습니다. 밸브 본체는 A105로 제작되었습니다. 역압 밸런스형의 구조적 특성을 가지고 있습니다. 연결 모드는 NPT이며 레버 작동 모드가 있습니다.

플러그 밸브
DN250 PN25 슬리브 플러그 밸브 RF WCB API599 터빈 작동

DN250 PN25 플러그 밸브는 API599 표준에 따라 만들어집니다. 밸브 본체는 A216 WCB로 제작되었습니다. 그것은 부드러운 밀봉 플러그 밸브의 구조적 특성을 가지고 있습니다. 연결 모드는 RF입니다. 그리고 터빈 작동 모드가 있습니다.

다섯 개의 백성 중 하나
DN100 PN10 3 방향 플로팅 볼 밸브 타입 RF

DN100 삼 Way Ball 밸브는 서비스 유체 흐름을 방향으로 고안된 밸브를 분리합니다.오히려 제한 또는 조절 기계, 증기, 가스, 오일, 원유, 산, 알칼리 및 기타 액체 및 기계적 액체 및 가스에 적합합니다

듀얼 플레이트 웨이퍼 타입 체크 밸브
24인치 150LB 듀얼 플레이트 웨이퍼 타입 체크 밸브 API 594 WCB

24인치 150LB 듀얼 플레이트 웨이퍼형 체크 밸브는 API 594 표준에 따라 제작되었습니다. 밸브 본체는 A216 WCB+SS316 재질로 제작되었습니다. 듀얼 플레이트 웨이퍼형 구조적 특성을 가지며, 웨이퍼 본체 설계를 채택했습니다. 연결 방식은 다음과 같습니다. 더블 플랜지, ASME B16.5.

메시지를 남겨주세요

    에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

제품

접촉