한국의

한국의

Get a Quote
제품

핫 제품

회사 뉴스

Installation of Large Diameter Ball Valves
Installation of Large Diameter Ball Valves
2026-03-09

Large diameter ball valves are commonly used in industries such as petroleum and chemical processing, power generation, long-distance pipeline transportation, and large-scale water treatment systems. If installation is not performed correctly, it may lead to sealing leakage, valve jamming, or structural stress damage. Therefore, proper installation practices are essential to ensure long-term stable operation.   1. Pre-installation Inspection   If pre-installation inspection is insufficient, operational failures are more likely to occur during service. First, inspect the valve body for transportation damage. If scratches, impact marks, or deformation are found on the valve body or sealing surfaces, installation should be stopped and the supplier should be contacted.   Next, verify valve model, pressure rating, and connection standards. If the system design pressure does not match the valve pressure class, operational safety risks may occur. For example, if a low-pressure class valve is mistakenly used in a high-pressure pipeline system, the valve body may experience plastic deformation under water hammer impact.   It is also necessary to check the condition of the ball surface and sealing rings. If there are scratches on the ball surface, sealing performance will be reduced. This is especially critical in gas transmission systems where micro-leakage is more likely.   2. Installation Direction   Large diameter ball valves usually have a flow direction marking. If the installation direction is incorrect, the following problems may occur: If the fluid flow direction matches the design direction, the operating torque will remain more stable. If the valve is installed in reverse, the stem may experience increased mechanical load, which will accelerate stem wear during long-term operation. For double-seal bidirectional ball valves, although bidirectional flow is allowed, installation according to the marked flow direction is still recommended to ensure more uniform sealing stress distribution. In high-temperature or steam systems, if the installation direction is incorrect, thermal expansion may accelerate sealing ring aging.   3. Pipeline Stress Control   Large diameter ball valves are heavy. If installed without proper support, additional bending moments may be transferred to flange connections. If pipeline systems experience axial displacement, pipeline supports should be installed for segmented fixation. If support structures are not provided, the valve body may bear long-term gravitational tensile load, eventually causing flange seal failure. It is generally recommended to install independent supports on both sides of large diameter ball valves. If the pipeline system is subject to thermal expansion and contraction, expansion compensation devices must be installed; otherwise, sealing surfaces may gradually fail.   4. Bolt Tightening Process   Flange connections of large diameter ball valves usually ...

Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
2026-03-02

This year’s Dervos annual conference was noticeably more grand and well-organized than in previous years.   In the morning session, each department delivered its annual work summary, reviewing key projects and achievements over the past year. Teams also openly shared the challenges encountered during implementation and the practical experience gained along the way.   Through this cross-department exchange, everyone developed a clearer understanding of one another’s responsibilities and workflows, laying a stronger foundation for future collaboration and communication.     In the afternoon session, the Outstanding Employee awards were presented. Each nominee shared their work achievements and practical experience, demonstrating a strong sense of responsibility and execution across different roles. It is precisely this proactive mindset, collaborative spirit, and down-to-earth working approach of Dervos employees that drives the team steadily toward its shared goals.     Showing up on time every single day throughout the year — that’s quite an achievement. Ian has now received the Perfect Attendance Award for two consecutive years.     During the annual conference, Dervos also presented medals and exclusive commemorative gifts to employees who have completed five years of service.     Dervos values the long-term dedication and consistent commitment of its team members, and sincerely appreciates the trust and contributions they have made over the years. For many at Dervos, the company is not only a platform for professional growth, but also a stage where shared goals and collective efforts come to life. In the evening, the annual conference transitioned into the banquet segment. Performances and interactive games were seamlessly interspersed, creating a relaxed yet organized atmosphere.     Laughter and cheers echoed throughout the venue, and in the moment the camera shutter clicked, the excitement and joy were captured in a single frame.     Eric said: "Let’s dream together, DERVOS's dream. A dream where we all play a part, piece by piece, it becomes a reality." For Dervos, the annual meeting is not just about "summarizing the year," but about bringing our hearts together, strengthening our resolve in doing the same thing, and then continuing to move forward, step by step, with steady progress.            

What Is the Difference Between Plug Valves and Ball Valves?
What Is the Difference Between Plug Valves and Ball Valves?
2026-02-20

Ball valves and plug valves differ significantly in several aspects, including structure, operating principle, mode of operation, flow control capability, sealing performance, and application scenarios. These differences enable the two types of valves to perform distinct roles in their respective fields.   Structural Differences   The ball valve, a design evolved from the plug valve, utilizes a spherical element as its core component. By rotating the ball 90° around the stem axis, the valve can be opened or closed. Its structure is straightforward, consisting primarily of a spherical closure element with a through-bore housed within the valve body.   In contrast, the structure of a plug valve is more complex. It comprises multiple components such as the valve body, bonnet, plug, seat, and stem. The closure element is a cylindrical or tapered plug that controls flow by rotating 90°, aligning or misaligning the port in the plug with the flow passage in the valve body to achieve opening or shutoff.   Operating Principle   The operating principle of a ball valve relies on the rotation of the ball to control the on-off flow of fluid. When the ball is in tight contact with the valve seat, the clearance between them is completely sealed, thereby preventing fluid leakage. When the ball rotates to a position disengaged from the seat, the fluid is allowed to flow freely through the passage inside the valve body.   The operating principle of a plug valve differs in that it primarily controls the flow passage by rotating the plug element to open or close the valve. In a plug valve, the plug is connected to the stem and rotates together with it to achieve flow control. The closure element is a tapered plug with a port, and the flow passage is designed to be perpendicular to the axis of the plug. This configuration enables the plug valve to operate more efficiently and reliably during opening and closing.   The operation of a ball valve is notably simple, requiring only a 90-degree rotation to achieve opening or closing. This design allows the flow passage to be opened or shut off quickly and smoothly when the ball is rotated by 90 degrees, providing both convenience and efficiency. In addition, ball valves offer relatively low flow resistance in the fully open or fully closed position, making them particularly suitable for applications that require rapid on-off operation.   By contrast, the operation of a plug valve is comparatively more complex, as several turns are typically required to complete the opening or closing action. The valve plug is designed in a cylindrical or tapered form and regulates fluid flow through rotation. Nevertheless, plug valves demonstrate excellent performance in flow regulation, enabling precise adjustment of the flow passage diameter and accurate control of flow rate. However, due to the relatively complicated operating process, plug valves are not well suited for frequent operation...

연성 철 게이트 밸브
加载中...

DN450 PN16 연성이 있는 철 게이트 밸브 GGG50 RF DIN

DN450 PN16 연성 철 게이트 밸브는 DIN 표준에 따라 제작되었습니다. 밸브 몸체는 GGG50으로 만들어졌습니다. F4 음용수 소프트 밸브의 구조적 특성과 구조적 길이를 가지고 있습니다.330mm. 연결 모드는 RF입니다. 그리고 그것은핸드 휠 작동 모드.

  • 지불:

    30% when order confirmed, 70% before shipment
  • 제품 원산지:

    China
  • 색:

    Customization
  • 배송 포트:

    Shanghai, China
  • 리드 타임:

    30~60 days Ex Works after order confirmation
  • Material:

    Ductile Iron
  • Method of Operation:

    Hand Wheel
지금 문의
제품 상세 정보

제품 설명

유형

연성 철 게이트 밸브

크기

DN450

압력

PN16

연결

RF

작업

핸드휠

본체 재질

연성이 있는 철

디자인 기준

소음

적용 가능한 매체

물, 석유 및 가스

특징

1. 연성 철 게이트 밸브는 인장 강도와 내구성이 높은 것으로 알려져 있어 까다로운 용도에 적합합니다.

2. 연성 철 게이트 밸브는 부식성 물질에 노출될 수 있는 열악한 환경에서 사용하기에 이상적입니다.

기술 도면

치수 확인

압력 테스트

명판 및 포장

검사 보고서

메시지를 남길

에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

관련 상품
웨이퍼 체크 밸브
16" 150LB 듀얼 플레이트 웨이퍼 체크 밸브 API594 WCB

16" 150LB 웨이퍼 체크 밸브는 API 594 표준에 따라 제작되었습니다. 밸브 본체는 WCB로 제작되었습니다. 더블 디스크 및 내장형의 구조적 특성을 가지고 있습니다. 연결 모드는 웨이퍼입니다.

나이프 게이트 밸브
DN150 PN10 단방향 나이프 게이트 밸브 웨이퍼 RF 주철

DN150 PN10 단방향 나이프 게이트 밸브 단일 피스의 스테인리스 스틸 본체 디자인이 특징이며 범용에서 가혹한 매체에 이르는 응용 분야에서 테스트된 성능을 제공합니다.

볼밸브 및 체크밸브 교체
헝가리 MOL 정유소 업그레이드 프로젝트에 DERVOS 밸브 적용

헝가리에 위치한 MOL의 정유소에는 다음이 필요합니다. 일반 볼 밸브 및 점검 밸브 교체 최적의 성능을 유지합니다. MOL의 신뢰받는 체크 및 볼 밸브 공급업체인 DERVOS 는 계속해서 작동을 위한 볼 밸브를 제공하고 있습니다. 이 프로젝트에서 DERVOS는 석유 및 가스 응용 분야의 유체 제어를 위한 고성능 볼 밸브 및 체크 밸브를 일괄 공급했습니다. 다양한 종류와 사양의 볼이 필요했습니다. 다양한 운영 및 밀봉 요구 사항을 충족하는지 확인하십시오. 파이프라인 시스템.

스윙 체크 밸브
16" CL 150 단일 디스크 스윙 체크 밸브, 본체 CF8M, API 594, 웨이퍼 연결

16" CL150 단일 디스크 스윙 체크 밸브는 API 594 표준에 따라 제작되었습니다. 밸브 본체는 ASTM A351 CF8M으로 만들어졌습니다. 싱글 디스크, 스윙 스타일의 구조적 특징을 가지고 있습니다. 그것의 연결 모드는 웨이퍼입니다.

금속 장착 러그 ss 버터 플라이 밸브 클래스 150
트리플 오프셋 버터 플라이 밸브 금속 장착 러그 16 인치

16 인치 3 중 오프셋 버터 플라이 밸브는 금속 시트, 스테인리스 스틸 cf8m 본체, 디스크 및 스템으로 설계되었습니다. 기어 박스가있는 완전히 러그 된 버터 플라이 밸브는 API 609에 따라 클래스 150 설계 압력을가집니다. 디자인 기능1. 작은 양, 경량, 간단한 구조2. 다층 금속 장착 / 완전히 금속 장착3. 방화 설계4. 폭발 방지 스템5. 쉬운 운영을위한 작은 토크 값6. 믿을 수있는 바다 표범 어업은 제로 누설 요구에 응할 수있었습니다7. 흐름 조절 기능8. 밀봉면의 마모를 최소화하기위한 트리플 편심 디자인 빠른 세부 사항 유형 나비   판막 크기 16 인치 압력 ans   150 구조 삼루타   편심, 삼중 오프셋, 금속 시트 연결 타입 돌기   유형 조작 변속 장치   움직이는 디자인 코드 API   609 면 대면 저 같은   b16.10 연결 종료 저 같은   b16.5 테스트 & amp;   검사 API   598 바디 재료 a351   cf8m 온도 범위 -29 ℃ ~ + 425 ℃ 신청 물,   석유 가스 재료 아니 부품 이름 탄소강   ASTM astm에 합금 강철 스테인리스   강철에서 ASTM으로 wcb 화장실 화장실 c5 cf8 cf8m cf3 cf3m 1 신체 a216 화장실 a217 화장실 a217 화장실 a217 c5 a351 cf8 a351 cf8m a351 cf3 a351 cf3m 2 차축 부시 아래 ptfe 또는 스테인리스   흑연 나선 상처 삼 줄기 a182 f6 a182 f304 a182 f304 a182 f304 a182 f304 a182 f316 a182 f304l a182 f316l 4 좌석 링 f6 스텔 라이트 6 스텔 라이트 6 스텔 라이트 6 a182 f304 a182 f316 a182 f304l a182 f316l 5 나비 판 a216 화장실 a217 화장실 a217 화장실 a217 c5 a351 cf8 a351 cf8m a351 cf3 a351 cf3m 6 잠금 링 a105 a182 f22 a182 f22 a182 f22 a182 f304 a182 f316 a182 f304l a182 f316l 7 핀 탄소강 또는 합금강 8 나사 탄소강 또는 합금강 9 최고 차축 부시 ptfe 또는 스테인리스   흑연 나선 상처 10 포장 흑연 + SS304 11 볼트 a193 b7 a193 b7 a193 b7 a193 b7 a193 b8 a193 b8 a193 b8 a193 b8 12 너트 a194 2 시간 a194 2 시간 a194 2 시간 a194 2 시간 a194 gr.8 a194 gr.8 a194 gr.8 a194 gr.8 13 볼트 a193 b7 a193 b7 a193 b7 a193 b7 a193 b8 a193 b8 a193 b8 a193 b8 14 너트 a194 2 시간 a194 2 시간 a194 2 시간 a194 2 시간 a194 gr.8 a194 gr.8 a194 gr.8 a194 gr.8 15 멍에 a216 화장실 a217 화장실 a217 화장실 a217 c5 a351 cf8 a351 cf8m a351 cf3 a351 cf3m 16 선 a182 f6 a182 f304 a182 f304 a182 f304 a182 f304 a182 f316 a182 f304l a182 f316l

리프트 체크 밸브
1" 2500LB 압력 자체 밀봉 리프트 체크 밸브 FNPT F316L

1" 2500LB 체크 밸브는 ASME B16.34 표준에 따라 만들어집니다. 밸브 본체는 F316L로 만들어집니다. 리프팅 유형, 압력 자체 밀봉, 기존 직경의 구조적 특성이 있습니다. 연결 모드는 FNPT입니다.

트리플 오프셋 버터 플라이 밸브 제조업체
트리플 편심 버터 플라이 밸브 30 ​​인치 150lb wcb 플랜지

편심 버터 플라이 밸브에는 3 중 오프셋 설계가 있습니다. 밸브 작동 중 밀봉면의 작은 마모로 인해 밀봉 성능이 우수하고 수명이 길다. 30 인치 버터 플라이 밸브는 ansi 150 이중 플랜지 연결 및 완전 금속 시트로 설계되었습니다. 빠른 세부 사항 유형 나비   판막 크기 30   인치 설계 압력 아니   150 구성 삼루타   오프셋 / 삼중 편심 연결 타입 rf   이중 플랜지 타입 조작 변속 장치   조작 디자인 코드 API   609 면 대면 asmeb16.10 연결 종료 asmeb16.5 테스트 & amp;   검사 API   598 바디 재료 a216   wcb 온도 범위 -29 ℃ ~ + 427 ℃ 신청 물,   석유 가스 사용 가능한 제품 범위 표준 크기 : 2 인치 ~ 150 인치 설계 압력 : 150lb ~ 900lb 밸브 연결 : 플랜지, 러그, 웨이퍼, 맞대기 용접 (bw) 밸브 작동 : : 레버 / 렌치, 기어 박스, 전동식, 공압식 바디 재질 : 탄소강 WCB, 스테인레스 스틸 cf8 / cf8m / cf3 / cf3m, 저온 스틸 lcb / lcc 시트 재질 : 완전 금속 시트, ss + graphite 시트

체크 밸브
단일 디스크 웨이퍼 체크 밸브 6 인치 150LB

API 594,에 따라 설계된 6인치 150LB 단일 디스크 웨이퍼 체크 밸브,에는 하나의 디스크와 웨이퍼 연결.이 있으며 -29 ~ 350섭씨 온도.에서 최고의 성능을 보입니다.

스윙 체크 밸브
본체 A105N, API602, NPT 연결, 2'' 800LB 스윙 체크 밸브

2" 800LB 스윙 체크 밸브는 API 602 표준에 따라 제작되었습니다. 밸브 몸체는 ASTM A105N으로 제작되었습니다. 볼트형 커버, 스윙 유형의 구조적 특성을 가지고 있습니다. 연결 모드는 NPT입니다.

틸팅 디스크 체크 밸브
10" 150LB 틸팅 디스크 체크 밸브 WCB 웨이퍼 API6D

10" 150LB 틸팅 디스크 체크 밸브는 API 6D 표준에 따라 제작되었습니다. 밸브 본체는 A216 WCB+SS316으로 제작되었습니다. 사판형의 구조적 특징을 가지고 있습니다. 연결 방식은 웨이퍼입니다.

듀얼 플레이트 웨이퍼 타입 체크 밸브
12인치 150LB 듀얼 플레이트 웨이퍼 타입 체크 밸브 A995 4A API594

12인치 150LB 듀얼 플레이트 웨이퍼 체크 밸브는 API594 표준에 따라 제작되었습니다. 밸브 본체는 A995 4A 재질로 제작되었으며, 듀얼 플레이트 웨이퍼 타입의 구조적 특성을 가지고 있습니다. 연결 방식은 LUG RF입니다.

볼 밸브
ISO17292 DN25 PN40 플로팅 볼 밸브 EN1092-1 B1 A105 레버

DN25 PN40 볼 밸브는 ISO17292 표준에 따라 제작되었습니다. 밸브 본체는 ASTM A105로 만들어졌습니다. 플로팅 볼, 풀 보어, 방화 및 정전기 방지의 구조적 특성을 가지고 있습니다. 연결 모드는 EN1092-1 B1입니다. 그리고 레버 조작 모드가 있습니다.

메시지를 남겨주세요

    에 관심이 있다면 우리의 제품과한 자세한 내용을 알고 싶다면,메시지를 남겨주십시오 여기,우리가 응답할 것입니다 당신은 빨리 우리가 할 수 있습니다.

제품

접촉